2.2   generator coMpartMents
Whether the generator set is being installed inside a 
compartment  specifically  manufactured  to  house  a 
generator or inside a compartment that the installer 
constructs, the compartment must meet certain spec-
ifications as outlined in the following sections:
2.2.1  coMpartMent sIze
Plan the compartment size carefully. Provide a mini-
mum clearance of 1/2 inch (13 mm) on the front and 
top, 1/2 inch (25 mm) on the left side, two (2) inches 
on the right side, and 2-1/2 inch (63.5 mm) from the 
back for air circulation AFTER the compartment has 
been  lined  with  metal  and  sound  insulation  (Figure 
2.3).
Figure 2.3 – Clearances
2-1/2" Clearance
in Back
1/2" Clearance on Top
2" Right Side
1/2"
in Front
Insulation
Plywood
Compartment
18" Cleara
nce 
Recommended
Belo
w (Mini
mu
m 12"
)
1/2" Left Side
NOTE:
Refer  to  “Figure  1.2  –  Major  Features  and 
Dimensions”.
2.2.2  coMpartMent constructIon
•  The generator compartment should be either con-
structed  of,  or  lined  with,  26-gauge  galvanized 
steel.
NOTE:
Aluminum  is  NOT  an  acceptable  alternative  
to  galvanized  steel  due  to  aluminum’s  low  
melting point.
•  If the compartment is lined with galvanized steel, 
it may be constructed of any material. The manu-
facturer  recommends  that  the  compartment  be 
constructed of 1/2-inch thick plywood (not strand-
board), with the floor made of a double thickness 
of 1/2-inch plywood with the grain of the wood at 
cross section for added strength (Figure 2.4).
•  If  constructing  a  compartment,  line  the  exterior 
(underside)  of  the  compartment  floor  with  26-
gauge galvanized steel.
Figure 2.4 – Typical Compartment Construction
•  All  seams,  splices  and  joints  of  the  compart-
ment  walls  (unless  vapor  tight  by  design)  should  
be  caulked  to  prevent  poisonous,  flammable  or 
explosive  vapors  from  entering  the  vehicle  inte-
rior.
NOTE:
Caulking must be done so that the caulking mate-
rial  will  stay  in  place  permanently.  Pressing  such 
materials  as  putty  tape  onto  joints  and  seams  is 
NOT acceptable. A high quality silicone rubber base 
sealant is recommended.
•  Holes  and  openings  made  in  the  compartment 
walls to allow for the passage of electrical conduit, 
conductors, hoses, cables, etc., into the vehicle liv-
ing  area  must  be  sealed  vapor  tight  with  silicone 
rubber base sealant.
•  If flexible metal conduit is used, it must be sealed 
internally at the end where it terminates inside the 
compartment’s electrical junction box. 
NOTE:
Flexible metal conduit, due to its unique construc-
tion, is NOT vapor tight along its entire length.
•  Seams and joints of the galvanized steel (whether 
used as a liner or for the compartment itself) must 
be lapped and mechanically secured. Such seams 
may  be  manufactured,  welded,  bolted,  riveted  or 
screwed.  Manufactured  lock  seams  are  shown  in 
Figure  2.5.  Installer  constructed  compartments 
typically utilize a standard lap joint.
•  After  the  compartment  has  been  metal  lined  and 
vapor sealed, line the compartment interior walls 
and ceiling with an approved, nonflammable sound 
insulating material. See Section 2.2.3.
section 2 – Installation
recreational vehicle generator