Guardian Technologies 004708-0 Manual De Usuario

Descargar
Página de 52
 4 
  1.  Generator Air Intake
  2.  Engine Start/Stop Switch
 3. Fuse
  4.  Optional Remote Panel Receptacle (Side View)
  5.  Generator AC Output Leads (Side View)
  6.  Fuel Primer Switch
 7. Circuit 
Breaker
 8. Starter 
Contactor
 9. Fuel 
Inlet
 10.  Fuel Pump (Behind Access Panel)
 11.  Fuel Filter (Side View)
 12.  Oil Filter
 13.  Oil Drain Cap
 14.  Oil Dipstick
 15.  Air Filter (Behind Access Panel)
 16.  Oil Fill
 17.  Spark Plug
  18  External Vacuum Port (model 004708-0 only)
Sectio n 1 – General Information
Recreational Vehicle Generator
Please record the following information from the generator DATA DECAL or information decal.
 
1. Model 
Number 
_____________________  
2. Serial 
Number 
__________________
 
3. kW 
Rating 
_________________________  
4. Rated 
Voltage 
__________________
I
t
r
e
,
e w a
D
W
AC
*
S E R V IC E
A C C E S S
P A N E L
OIL LEVEL:
CHECK DAILY
AIR FILTER:
CLEAN PREFILTER
EVERY 100 HOURS.
REPLACE ELEMENT
EVERY 250 HOURS.
OIL & OIL FILTER:
CHANGE EVERY 100
(IF NECESSARY)
EVERY 500 HOURS.
HOURS. REPLACE PLUGS
PLUGS EVERY 100
INSPECT & CLEAN
SPARK PLUGS:
REPLACEMENT INFORMATION
*
PERFORM MORE OFTEN IN DUSTY CONDITIONS
AIR FILTER LOCATED BEHIND PANEL.
MAINTENANCE SCHEDULE
AIR FILTER P/N:
0D3262
070185
OIL FILTER P/N:
SPARK PLUG P/N:
072347
OIL CAPACITY WITH FILTER:
0.8L/0.84QT
TEMPERATURE
SAE VISCOSITY
32°F AND HIGHER
10°F TO 100°F
0°F TO 80°F
-20°F TO 50°F
5W-30
10W-30
15W-40
30
WHEN SERVICE OR PARTS ARE NEEDED IN
THE USA OR CANADA, CONTACT THE GENERAC
SERVICE LOCATOR AT 1-800-333-1322.
HOURS. (OR ANNUALLY)
PREFILTER P/N:
0D4511
FUEL FILTER P/N:
0D7515
FUEL FILTER:
CHANGE EVERY 400
HOURS. (OR ANNUALLY)
*
*
P R I M E
F U E L
S T O P
S T A R T
3 0 A
C . B .
1 5 A
F U S E
CONTROL CENTER
1
2
3
7
6
10/15
17
8
14,16
13
12
4
18
5
9/11
 1.1   GENERATOR IDENTIFICATION