3.13.2 RETURN TO SERVICE
To return the unit to service after storage, proceed 
as follows:
1.  Check the tag on the engine for oil viscosity and 
classification. Verify that the correct recommend-
ed oil is used in the engine (see the "Engine Oil 
Requirements" section). If necessary, drain and 
refill with the proper oil.
2.  Check the state of the battery. Fill all cells of 
unsealed batteries to the proper level with dis-
tilled water. DO NOT USE TAP WATER IN THE 
BATTERY. Recharge the battery to 100 percent 
state of charge, or, if defective, replace the battery.
3.  Clean and wipe the entire generator.
4.  Reconnect the battery. Observe battery polarity. 
Damage may occur if the battery is connected 
incorrectly.
5.  Turn OFF all electrical loads. Add fuel if neces-
sary and then start the engine.
6.  Allow the unit to warm up thoroughly.
7.  Apply electrical loads to at least 50 percent of the 
unit’s rated wattage capacity.
8.  When the engine is thoroughly warmed up, shut 
it down.
9.  The generator is now ready for service.
‹