HP 590259-421 Manual De Usuario

Descargar
Página de 48
Power Specifications
Power Specifications
Power Specifications
Power Specifications
To review typical system power ratings use the Power Advisor which is
available via the online tool located at URL: 
- Click on the system of interest. Example: DL165 G7
- Follow the instructions of the next screens.
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
(per power supply)
Rated Steady-State Power 750 W (at 100 VAC),
750W (at 200 VAC)
Maximum Peak Power
750 W (at 100 VAC),
750 W (at 200 VAC)
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
Altitude
Altitude
Altitude
Altitude
Operating
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 609
m/min (2000 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 609 m/min (2000 ft/min).
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions
were measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).
Idle
Idle
Idle
Idle
 
LWAd
6.03 B
LpAm
46.1 dBA
Operating
Operating
Operating
Operating
 
LWAd
6.08 B
LpAm
46.4 dBA
Emissions Classification
Emissions Classification
Emissions Classification
Emissions Classification
(EMC)
(EMC)
(EMC)
(EMC)
FCC Rating
FCC Rating
FCC Rating
FCC Rating
Class A
QuickSpecs
HP ProLiant DL165 Generation 7 (G7)
HP ProLiant DL165 Generation 7 (G7)
HP ProLiant DL165 Generation 7 (G7)
HP ProLiant DL165 Generation 7 (G7)
Technical Specifications
DA - 13602   Worldwide — Version 23 — November 14, 2011
Page 46