15 • 20 • 30 • 48 • 50 kW 
application & engineering data
®
GENERATOR SPECIFICATIONS
Type
Synchronous
Rotor Insulation Class
H (15 & 20 kW) or F (30 & 50 kW)
Stator Insulation Class
H
Telephone Interference Factor (TIF)
<50
Alternator Output Leads 1-Phase
3 wire
Alternator Output Leads 3-Phase
6 wire
Bearings
Single Sealed Cartridge
Coupling
Direct, Flexible Disc
Excitation System
Direct
VOLTAGE REGULATION
Type
Electronic
Sensing
Single Phase
Regulation
± 1%
Features
Adjustable Voltage & Gain
GOVERNOR SPECIFICATIONS
Type
Electronic Isochronous
Steady State Regulation
± 0.25%
ELECTRICAL SYSTEM
Battery Charge Alternator
50 Amp (15 & 20 kW) or 70 Amp (30, & & 50 kW)
Smart Battery Charger
2 Amp
Recommended Battery
Group 27F, 700 CCA
System Voltage
12 Volts
GENERATOR FEATURES
Revolving field heavy duty generator
Directly connected to the engine
Operating temperature rise 120°C above a 40°C ambient
Class H insulation is rated at 150°C rise at 25°C ambient
Class F insulation is rated at 145°C rise at 25°C ambient
All models fully prototype tested
ENCLOSURE FEATURES
Steel weather protective enclosure with aluminum  roof
Ensures protection against mother nature. Electrostatically applied textured epoxy paint 
for added durability.
Enclosed critical grade muffler
Quiet, critical grade muffler is mounted inside the unit to prevent injuries and 
maximize sound dampening.
Small, compact, attractive
Makes for an easy, eye appealing installation.
SAE
Sound attenuated enclosure ensures quiet operation.
(All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271)