Generac QT Manual De Usuario

Descargar
Página de 56
SPECIFICATIONS
GENERATOR
Type ............................................................................. Synchronous
Rotor Insulation ....................................................................Class F
Stator Insulation ...................................................................Class F
Total Harmonic Distortion .........................................................< 5%
Telephone Interference Factor (TIF) ..........................................< 50
Alternator Output Leads 3-phase ........................................... 4-wire
Bearings .........................................................................Sealed Ball
Coupling .......................................................................Flexible Disc
Load Capacity (Standby Rating) ............................................20kW*
*
  NOTE: Generator rating and performance in accordance with ISO8528-5, BS5514, SAE J1349, 
ISO3046 and DIN 6271 Standards. KW rating is based on LPG fuel and may derate with natural 
gas.
Excitation System ....................................................................Direct
Generator Output Voltage/kW - 60 Hz 
kW 
Amp  CB Size
  120/240V, 1-phase, 1.0 pf 
20 
83 
100
  120/208V, 3-phase, 0.8 pf 
20 
69 
80
Generator Locked Rotor KVA Available @ Voltage Dip of 35%
  Single-phase or 208 3-phase ............................................. 34 KVA
ENGINE
Make ................................................................................... Generac
Model ..................................................................................... In  Line
Cylinders and Arrangement ............................................................ 4
Displacement ....................................................................... 1.5  Liter
Bore ...................................................................................... 2.97  in.
Stroke ................................................................................... 3.23  in.
Compression Ratio ...............................................................9.4-to-1
Air Intake System ...............................................Naturally Aspirated
Valve Seats ................................................................... Replaceable
Lifter Type .......................................................................... Hydraulic
Engine Parameters
Rated Synchronous RPM ..............................................60 Hz, 3600
HP at rated kW ..................................................................60 Hz, 32
Exhaust System
Exhaust Flow at Rated Output 60 Hz .................................. 177 cfm
Exhaust Temperature at Rated Output .................................. 910° F
Combustion Air Requirements (Natural Gas)
Flow at rated power, 60 Hz ................................................... 70 cfm
Governor
Type .................................................................................. Electronic
Frequency Regulation ...................................................Isochronous
Steady State Regulation ........................................................± .25%
Adjustments:
  Speed ............................................................................ Selectable
‹
‹
Engine Lubrication System
Type of Oil Pump ...................................................................... Gear
Oil Filter .............................................................Full Flow, Cartridge
Crankcase Oil Capacity ....................................................4 U.S. qts.
COOLING SYSTEM
Type ....................................................................................... Closed
Water Pump .................................................................... Belt Driven
Fan Speed ................................................................................ 2550
Fan Diameter .....................................................................15 inches
Fan Mode ..............................................................................Pusher
Air Flow (inlet air including alternator and
  combustion air) .......................................................... 1528 ft3/min.
Coolant Capacity ...........................................................2.0 U.S. gal.
Heat Rejection to Coolant ..........................................107,000 Btu/h
Maximum Operating Air Temp. on Radiator ..............60° C (150° F)
Maximum Ambient Temperature ................................50° C (140° F)
FUEL SYSTEM
Type of Fuel ......................................... Natural Gas, Propane Vapor
Carburetor ...................................................................... Down Draft
Secondary Fuel Regulator .................................................Standard
Fuel Shut-off Solenoid ........................................................Standard
Operating Fuel Pressure  ...................... 5 in. - 14 in. Water Column
Fuel Consumption - ft
3
/hr (Natural Gas/LPV)
 Exercise 
25% 
50% 
75% 
100%
 Cycle 
Load 
Load 
Load  Load
 60/24  124/49  188/75  250/99 315/125
ELECTRICAL SYSTEM
Battery Charge Alternator ............................................12V, 15 Amp
Static Battery Charger ............................................................2 Amp
Recommended Battery ...................................... Group 26, 525CCA
System Voltage .....................................................................12 Volts
Voltage Regulator
Type .................................................................................. Electronic
Sensing ........................................................................ Single-phase
Regulation ................................................................................± 1%
Features ................................................. V/F Adjustable, Adjustable 
Voltage and Gain LED Indicators
Power Adjustment for Ambient Conditions
Temperature Deration
  3% for every 10° C above °C ..................................................... 25
  1.65% for every 10° above °F .................................................... 77
Altitude Deration
  1% for every 100 m above m ................................................... 182
  3% for every 1000 ft. above ft. ................................................. 600
Controller .................................................R-100
‹
‹
‹
6-1
Standby Generator Sets
Specifications
GenSpec013  Rev.