Generac 000 & 8 Manual De Usuario

Descargar
Página de 56
  
11
NOTE:
Do not use the battery charger for more than 48 hours at one 
charge.
3.1 MAINTENANCE SCHEDULE
Follow the calendar intervals. More frequent service is required 
when operating in adverse conditions noted below.
Check Oil Level 
At Each Use
Change Oil ‡ 
*Every 100 hours or Every Season
Check Valve Clearance 
***Every Season
Service Air Filter 
** Every 200 hours or Every Season
Replace Spark Plug 
Every Season
‡  Change oil after first 30 hours of operation then every season.
*  Change oil and oil filter every month when operating under heavy load or in high 
temperatures.
** Clean more often under dirty or dusty operating conditions.  Replace air filter 
parts if they cannot be adequately cleaned.
***  Check valve clearance and adjust if necessary after first 50 hours of 
operation and every 100 hours thereafter.
3.2 PRODUCT SPECIFICATIONS
3.2.1 GENERATOR SPECIFICATIONS
Rated. Power ....................................................................7.0/8.0 kW**
Surge Power .......................................................................8.7/12.0 kW
Rated AC Voltage ......................................................................120/240
Rated Max AC Load
  Current @ 240V (7.0/8.0 kW) ............................25 Amps/30 Amps**
  Current @ 120V ................................................................20 Amps**
Rated Frequency .................................................... 60 Hz @ 3600 RPM
Phase ................................................................................ Single Phase
**  Maximum wattage and current are subject to, and limited by, such factors 
as fuel Btu content, ambient temperature, altitude, engine condition, etc.. 
Maximum power decreases about 3.5% for each 1,000 feet above sea level; 
and will also decrease about 1% for each 6° C (10° F) above 16° C (60° F) 
ambient temperature.
3.2.2 ENGINE SPECIFICATIONS
Rated Horsepower @ 3600 RPM ....................................................14.5
Displacement ............................................................................... 410cc
Spark Plug Type ...................................Champion RC14YC or Equivalent
Spark Plug Gap ............................................... 0.030 inch or (0.76 mm)
Gasoline Capacity ............................................................ 8 U.S. gallons
Oil Type.................................... See Chart in "Adding Engine Oil" Section
Oil Capacity ................................................ w/ Filter Change = 1.5 Qts.
 
w/o Filter Change = 1.2 Qts.
Run Time/Fuel Consumption-1/2 Load .. 10 Hours / .80 gallons per hour
Class II Emission Certified
3.3 GENERAL RECOMMENDATIONS
The warranty of the generator does not cover items that have been 
subjected to operator abuse or negligence. To receive full value 
from the warranty, the operator must maintain the generator as 
instructed in this manual.
Some adjustments will need to be made periodically to properly 
maintain the generator.
All adjustments in the Maintenance section of this manual should 
be made at least once each season. Follow the requirements in the 
"Maintenance Schedule".
NOTE:
Once a year replace the spark plug and replace the air filter. 
A new spark plug and clean air filter assure proper fuel-air 
mixture and help the engine run better and last longer.
3.3.1 GENERATOR MAINTENANCE
Generator maintenance consists of keeping the unit clean and dry. 
Operate and store the unit in a clean dry environment where it will 
not be exposed to excessive dust, dirt, moisture or any corrosive 
vapors. Cooling air slots in the generator must not become clogged 
with snow, leaves, or any other foreign material.
Check the cleanliness of the generator frequently and clean when 
dust, dirt, oil, moisture or other foreign substances are visible on 
its exterior surface.
  Never insert any object or tool through the air 
cooling slots, even if the engine is not running.
NOTE:
DO NOT use a garden hose to clean generator. Water can enter 
the engine fuel system and cause problems. In addition, if water 
enters the generator through cooling air slots, some water will 
be retained in voids and crevices of the rotor and stator winding 
insulation. Water and dirt buildup on the generator internal 
windings will eventually decrease the insulation resistance of 
these windings.
3.3.2  TO CLEAN THE GENERATOR
Use a damp cloth to wipe exterior surfaces clean.
• 
A soft, bristle brush may be used to loosen caked on dirt, oil, 
• 
etc.
A vacuum cleaner may be used to pick up loose dirt and 
• 
debris.
Low pressure air (not to exceed 25 psi) may be used to 
• 
blow away dirt. Inspect cooling air slots and openings 
on the generator. These openings must be kept clean and 
unobstructed.
Section 3 — Maintenance
Portable Generator System