Generac 005606-0 Manual De Usuario

Descargar
Página de 20
 14 
4.1  BATTERY SERVICE (REPLACEMENT)
The battery shipped with the generator has been provided fully 
charged. Caution must be taken when connecting the battery.
NOTE:
A battery may lose some of it’s charge when not in use for 
prolonged periods of time. (See the "Know the Generator" 
section.)
To replace the battery:
Remove end panel as shown in Figure 5 in the "Know the 
• 
Generator" section.
Remove hold-down bracket.
• 
Disconnect the RED battery cable to the battery Positive 
• 
terminal (+).
Disconnect the BLACK battery cable to the battery Negative 
• 
terminal (–).
To install a new battery:
• 
Reverse the steps above and follow Figure 18.
• 
Double check all connections to ensure they are in the correct 
• 
location and secure. See Figure 18.
Figure 18 - Battery Connections
NEGATIVE BATTERY
CABLE (BLACK)
NUT
LOCK WASHER
CABLE BOOT
FLAT WASHER
POSITIVE BATTERY
CABLE (RED)
SCREW
GROUND
(GREEN)
BATTERY CHARGER
(RED)
BATTERY CHARGER
(BLACK)
Battery Type:  CP12-10, 12V, 10AH
Section 4 — Battery Service
Portable Generator System