PAGE 34 — DCA45SSIU3 50 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #2 (12/19/08) 
GENERATOR START-UP PROCEDURE 
BEFORE STARTING 
Place the 
1. 
main, G.F.C.I., and aux. circuit breakers (Figure 
35) in the OFF position prior to starting the engine.
Main, Aux. and GFCI 
Figure 35. 
Circuit Breakers (OFF)
Make sure the 
2. 
voltage change-over board has been 
confi gured for the desired output voltage.
Connect the load to the 
3. 
receptacles or the output 
terminal lugs as shown in Figure 10. These load 
connection points can be found on the output terminal 
panel and the output terminal panel’s hard wire hookup 
panel. 
Tighten terminal nuts securely to prevent load wires 
4. 
from slipping out.
Close all engine enclosure doors (Figure 36).
5. 
Engine Enclosure Doors
Figure 36. 
  CAUTION
The engine’s exhaust contains harmful emissions. 
ALWAYS have adequate ventilation when operating. 
Direct exhaust away from nearby personnel.
  WARNING
NEVER manually start the engine with the main, GFCI or 
auxiliary
 circuit breakers in the ON (closed) position.
INCORRECT
CORRECT
STARTING
Place the
1. 
 voltage selector switch in the desired 
voltage position (Figure 37)..
Voltage Selector Switch
Figure 37. 
Preheat the engine glow plugs by turning the ignition 
2. 
key (Figure 38) to the “OPERATION” position.
Ignition Switch 
Figure 38. 
(Operation/PreHeat Position)
When the preheat lamp illuminates (Figure 39), turn the 
3. 
ignition key to the “start” position.  Once the engine 
starts, release the ignition key and allow it to return to 
the “operation” position (Figure 38).
Pre-Heat Lamp
Figure 39. 
Let the engine run for 3-5 minutes, listen and check 
4. 
for any abnormal sounds or smells. Check for fuel 
leaks, and noises that would associate with a loose 
cover or hardware. If any of the above mentioned 
conditions exists, shut-down the engine and correct 
the problem.