Grouping Channels & Linking Parameters
01V96i—Reference Manual
Using Mute Group Master
In addition to the Mute Group function that links the opera-
tion of channel [ON] buttons, the 01V96i features a Mute 
Group Master function that enables you to mute grouped 
channels using the Master Mute buttons in a manner similar 
to using a mute group on an analog mixing console. While 
this function is enabled, the [ON] buttons for grouped chan-
nels will not be linked.
1.
After you perform Step 5 in “Using Fader 
Groups and Mute Groups” on page 59
, use 
the cursor buttons to select the INPUT MUTE 
MASTER check box or OUTPUT MUTE MAS-
TER check box, then press [ENTER] to turn on 
the Mute Group Master function.
2.
When the Mute Master check box is checked, 
use the group MASTER MUTE buttons to 
mute or unmute the groups.
If channels are muted via the Mute Master function, the 
channel [ON] button indicators flash. It is useful if you 
assign the MASTER MUTE buttons to USER DEFINED 
KEYS buttons.
Linking EQ and 
Compressor Parameters
Follow the steps below to link EQ or compressor parameters 
for Input Channels or Output Channels. This function 
enables you to set EQ or compressor parameters for multiple 
channels to the same values simultaneously.
1.
Press the DISPLAY ACCESS [PAIR/GROUP] 
button repeatedly until one of the following 
pages appears.
• In  EQ  page
This page enables you to set EQ links (a–d) for Input 
Channels 1–32 and ST IN Channels 1–4.
• Out  EQ  page
This page enables you to set EQ links (e–h) for Bus Outs 
(1–8), Aux Outs (1–8) and Stereo Out.