Euphonix 840-07591-04 Manual De Usuario
Euphonix System 5 Installation Guide
System 5 Components
62
SDIF-2 or Slave Clock In (BNC): This connector can receive either an SDIF or Slave
Clock Sync signal (the FC727 automatically detects the signal type). An SDIF device must
send a Word Sync signal to this connector to interface properly. Slave Clock is a sync signal
(commonly implemented in Pro Tools systems and referred to as a super-clock) that runs
at 256 times the sample rate. Pro Tools users may optionally connect the Slave Clock output
from another Digidesign audio interface or synchronization unit (i.e., 888-24) to the Slave
Clk In connector to synchronize both devices. Cable not provided.
Clock Sync signal (the FC727 automatically detects the signal type). An SDIF device must
send a Word Sync signal to this connector to interface properly. Slave Clock is a sync signal
(commonly implemented in Pro Tools systems and referred to as a super-clock) that runs
at 256 times the sample rate. Pro Tools users may optionally connect the Slave Clock output
from another Digidesign audio interface or synchronization unit (i.e., 888-24) to the Slave
Clk In connector to synchronize both devices. Cable not provided.
Slave Clock Out (BNC): Pro Tools users may optionally connect the Slave Clk Out to an-
other Digidesign audio interface or synchronization unit (i.e., 888-24) to synchronize both
devices. This allows both a Digidesign I/O unit and the FC727 to be connected to the same
Pro Tools computer. If Slave Clk In has a valid sync signal, it is passed through to Slave
Clk Out. If Slave Clk In does not have a valid sync signal, the lowest numbered bank of
eight inputs that is locked and in use is selected as the clock source (cable not provided).
other Digidesign audio interface or synchronization unit (i.e., 888-24) to synchronize both
devices. This allows both a Digidesign I/O unit and the FC727 to be connected to the same
Pro Tools computer. If Slave Clk In has a valid sync signal, it is passed through to Slave
Clk Out. If Slave Clk In does not have a valid sync signal, the lowest numbered bank of
eight inputs that is locked and in use is selected as the clock source (cable not provided).
MADI B In 1 / MADI B Out 1 (two BNC): Connect these MADI Ports to the DF64 or
optional SH612 Studio Hub (cable provided).
optional SH612 Studio Hub (cable provided).
Format B AES Sync In (female XLR): Connect this port to a digital sync reference.
Format B AES Sync Thru (male XLR): This signal is active regardless of selected sync
source.
source.
Format B Word In (BNC): Connect this port to a digital sync reference.
Format B Word Out (BNC): This signal is active regardless of selected sync source.