4. Setting up the B512DSP
OFF
If the switch is not actuated (OFF position) then the speaker
remains switched on and can only be deactivated via the
POWER switch 
.
A noise-gate allows you to eliminate unwanted noise during
signal  pauses.  This  is  done  by  a  circuit  that  mutes  the
output  when  the  signal  level  drops  below  a  preset
threshold. Use the NOISE GATE control to determine the
threshold  below  which  the  noise-gate  closes.
The  TH  LED  lights  up  as  soon  as  the  signal  level  drops
below the threshold value adjusted with the NOISE GATE
control 
 (the noise-gate closes).
The LED on the front indicates the following operating status:
Indicator
Operating status
BLUE light 
The device is switched on
BLUE light
(dimmed)
Device is on standby
 (if TIMED TURN-OFF activated)
VIOLET light
same function as CLIP LED 
^`
flashing RED
Device is overheating! 
Switch off the speaker until it cools down
Tab.  2.1:  Frontal  LED  operating  status
3. Setting up the B512DSP
The  sound  of  your  B512DSP  largely  depends  on  the  room
acoustics. Please observe the following hints to get the most out
of your B512DSP.
3.1 Tweeter
High  frequencies  are  the  very  part  of  the  audio  spectrum  that
ensure  a  clear  perception  of  sound  and  speech  intelligibility.
Although these frequencies can be located most easily, they are
also the first to be blocked acoustically. We therefore recommend
that you set up your speakers on speaker stands (not included),
so that the tweeter radiates its signals slightly above the heads
of the audience. This will ensure both an optimum dispersion of
the high-frequency content and a considerably improved speech
intelligibility.
Fig. 3.1: B512DSP mounted on a stand
3.2 How to avoid feedback
Always  place  the  microphones  (viewed  from  the  audience)
behind the B512DSP, never in front of it (Fig. 3.2). When you
wish  to  adjust  the  controls  on  the  B512DSP  while  holding  a
microphone, please approach the loudspeaker from the rear to
avoid  feedback.
Fig. 3.2: Right and wrong positioning
Since the B512DSP can be placed on the floor at an angle as
shown in the illustration below, you can also use it as a monitor
speaker  on  stage.  In  contrast  to  PA  speakers,  stage  monitors
are used to direct sound towards individual performers on stage.
When microphones are used, it is not easy to position the monitor
speakers, since the microphones are moved around in front of
them,  often  coming  very  close.  To  avoid  feedback,  it  is
recommended that you carefully select and direct the microphones
used.  Basically,  you  should  use  microphones  with  a  high
directivity,  i.e.  with  a  cardioid  or  hyper-cardioid  polar  pattern.
Never  hold  a  microphone  so  that  its  main  pick-up  area  points
directly towards the loudspeaker. When you hold it with its less
sensitive side towards the speaker box, you can move closer to
the speaker.
Microphones  with  a  cardioid  polar  pattern  should  always  be
directed at a 90° angle to the axis of the loudspeaker (Fig. 3.3,
left).  Microphones  with  a  hyper-cardioid  polar  pattern  should
always  be  positioned  at  an  acute  angle  to  the  axis  (Fig.  3.3,
right).
Fig. 3.3: The B512DSP as a monitor loudspeaker
+
If  you  encounter  persistent  feedback  problems,
consider  using  our  proven  FEEDBACK  DESTROYER
PRO  FBQ2496  for  line-level  signals.  For  signals  with
line  or  microphone  level,  we  recommend  our
BEHRINGER SHARK DSP110.