1 General 
VSE 002 External RS-485 Module 
 
VVSE2/EN M/B006 
 
 3
  
 
1. 
General 
External RS-485 Module VSE 002 is used to connect VAMP 
protection relays to a RS-485 bus. 
Additionally this module can be used with any device, which has a 
RS-232 or TTL serial interface, when an RS-485 interface is 
required. 
2. 
Power supply 
The power for the module is taken from pin 9 of the D-connector or 
from an external power supply interface.  There is a screw terminal 
(X1, see figure 1) for connecting an external  +9...12Vdc power 
supply. 
3. 
Module interface to the VAMP 
relays or master device 
The physical interface to the device is a 9-pin D-connector.  The 
signal levels may be either TTL or RS-232. 
The TTL/RS-232 interface of the modules is: 
Pin number 
TTL mode 
RS-232 mode 
RXD (in) 
RXD (in) 
TXD (out) 
TXD (out) 
RTS (in) 
RTS (in) 
 
 
 
 
GND 
GND 
 
 
+8V (in) 
+8V (in) 
 
 
The active state of the RTS signal is positive 
voltage (> +3V) in both TTL and RS-232 modes.