Siemens 9350 Manual De Usuario

Descargar
Página de 176
9300 Series User’s Guide
I/O Connections
Chapter 7 - Hardware Reference 
Page 155
Digital Inputs
The meter supports four digital inputs. These can be used for monitoring the 
condition of an external contact, or for pulse counting applications.
Analog Inputs
Two types of analog input ports are available when you order a meter (refer to 
your meter’s label to determine what type you ordered): 
Description
Specification
Input Type
Self-excited (internal 30 VDC supply)
Inputs
S1, S2, S3, S4
Application
Dry contact sensing, or with external excitation.
Wire
28 to 16 AWG (0.1 to 1.3 mm
2
)
Connector Type
Captured wire
Max. Pulse Width
25 pulses per second
Specification
0-20 mA (scalable to
4-20 mA) Option
0-1 mA Option
Input Impedance
25 Ω
475 Ω
Maximum Source 
Impedance 
500 Ω
10 kΩ
Accuracy
±0.3% of full-scale
Inputs
AI1, AI2, AI3, AI4
Connectors
Phoenix captured-wire
Update Rate
1 Hz
Channel to Channel 
Isolation
None
Max. Common Mode 
Voltage
30 V
Standards Compliance
IEC 61000-4-4 fast transient test with capacitive clamp (4 kVp-p@2.5 
kHz for 1 min)
C
S3
S4
S2
S1
R
S1
C (+)
30 VDC 
Internal 
Supply
Optically coupled 
solid state relay
Internal Circuit
Digital Inputs
External Dry 
Contacts
Polarity 
for SSR 
Contact 
shown.