Pressure Relief Procedure
1.
Engage trigger lock.
2.
Air-Powered Pumps only: Close the bleed-type 
master air valve.
Hydraulic-Powered Pumps only: Close the hydraulic 
supply line valve first, then the return line valve.
3.
Disengage the trigger lock.
4.
Hold a metal part of the gun firmly to a grounded 
metal pail. Trigger the gun to relieve pressure.
5.
Engage the trigger lock.
6.
Open all fluid drain valves in the system, having a 
waste container ready to catch drainage. Leave 
drain valve(s) open until you are ready to spray 
again.
7.
If you suspect the spray tip or hose is clogged or 
that pressure has not been fully relieved after follow-
ing the steps above, VERY SLOWLY loosen tip 
guard retaining nut or hose end coupling to relieve 
pressure gradually, then loosen completely. Clear 
hose or tip obstruction.
CAUTION
Hydraulic-Powered Pumps only: When shutting down 
the hydraulic system, always shut off the hydraulic 
supply line shutoff valve first, and then the return line 
shutoff valve to prevent overpressurizing the motor or 
its seals. When starting the hydraulic system, open 
the return line shutoff valve first.