Hitachi SJ300-037HFE Manual De Usuario

Descargar
Página de 289
SJ300 Inverter
Configur
ing Dr
iv
P
a
ra
met
e
rs
3–35
NOTE: Two sets of overload restriction parameters are available. The set that is in use may be 
selected by means of an intelligent input terminal (see 
B025
Overload restriction 
setting (2)
Sets the level for overload 
restriction (2), between 50% 
and 200% of the rated 
current of the inverter, 
setting resolution is 1% of 
rated current
✘ ✔ rated current times 
1.50
A
>b025 OLOAD
2LEVEL   0024.8A
B026
Deceleration rate at 
overload restriction (2)
Sets the deceleration rate (2) 
when inverter detects 
overload, range is 0.1 to 
30.0, resolution is 0.1.
✘ ✔ 1.00 1.00 1.00
sec.
>b026 OLOAD
2CONST     01.00
“B” Function
Run 
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name
Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)