Hitachi SJ300-037HFE Manual De Usuario

Descargar
Página de 289
“H” Group: Motor Constants Functions
Configur
ing Dr
iv
P
a
ra
meters
3–64
H224 Motor constant J,
2nd motor
Ratio (unit-less), range is
1.0 to 1000
✘ ✘
According to 
inverter rating
>H224 2AUX
J        000.055
H030 Auto-tuned motor 
constant R1, 1st motor
Auto-tuning data
✘ ✘
According to 
inverter rating
Ohm
>H030 AUX
A-R1   00.489ohm
H230 Auto-tuned motor 
constant R1, 2nd motor
Auto-tuning data
✘ ✘
According to 
inverter rating
Ohm
>H230 2AUX
A-R1   00.489ohm
H031 Auto-tuned motor 
constant R2, 1st motor
Auto-tuning data
✘ ✘
According to 
inverter rating
Ohm
>H031 AUX
A-R2   00.355ohm
H231 Auto-tuned motor 
constant R2, 2nd motor
Auto-tuning data
✘ ✘
According to 
inverter rating
Ohm
>H231 2AUX
A-R2   00.355ohm
H032 Auto-tuned motor 
constant L, 1st motor
Auto-tuning data
✘ ✘
According to 
inverter rating
mH
>H032 AUX
A-L     005.12mH
H232 Auto-tuned motor 
constant L, 2nd motor
Auto-tuning data
✘ ✘
According to 
inverter rating
mH
>H232 2AUX
A-L     005.12mH
H033 Auto-tuned motor 
constant I
0
, 1st motor
Auto-tuning data
✘ ✘
According to 
inverter rating
A
>H033 AUX
A-I0     008.02A
H233 Auto-tuned motor 
constant I
0
, 2nd motor
Auto-tuning data
✘ ✘
According to 
inverter rating
A
>H233 2AUX
A-I0     008.02A
H034 Auto-tuned motor 
constant J, 1st motor
Auto-tuning data
✘ ✘
According to 
inverter rating
>H034 AUX
A-J     0000.055
H234 Auto constant J,
2nd motor
Auto-tuning data
✘ ✘
According to 
inverter rating
>H234 2AUX
A-J     0000.055
H050 PI proportional gain for 
1st motor
Range is 0.0 to 99.9 / 100.0 
to 999.9 / 1000%
✔ ✔ 100
100
100
%
>H050 AUX
KSP      0100.0%
H250 PI proportional gain for 
2nd motor
Range is 0.0 to 99.9 / 100.0 
to 999.9 / 1000%
✔ ✔ 100
100
100
%
>H250 2AUX
KSP      0100.0%
H051 PI integral gain for 1st 
motor
Range is 0.0 to 99.9 / 100.0 
to 999.9 / 1000%
✔ ✔ 100
100
100
%
>H051 AUX
KSI      0100.0%
H251 PI integral gain for 2nd 
motor
Range is 0.0 to 99.9 / 100.0 
to 999.9 / 1000%
✔ ✔ 100
100
100
%
>H251 2AUX
KSI      0100.0%
H052 P proportional gain 
setting for 1st motor
Range is 0.00 to 10.00
✔ ✔ 1.00 1.00 1.00
>H052 AUX
KSPP      001.00
H252 P proportional gain 
setting for 2nd motor
Range is 0.00 to 10.00
✔ ✔ 1.00 1.00 1.00
>H252 2AUX
KSPP      001.00
H060 0Hz SLV limit for 1st 
motor
Range is 0.0 to 100.0%
✔ ✔ 100. 100. 100.
%
>H060 AUX
0SLV-LMT  100.0%
H260 0Hz SLV limit for 2nd 
motor
Range is 0 to 100.0%
✔ ✔ 100. 100. 100.
%
>H260 2AUX
0SLV-LMT   100.0%
H070 Terminal selection PI 
proportional gain setting
Range is 0 to 99.9 / 100.0 to 
999.9 / 1000%
✔ ✔
100.0
100.0
100.0
%
>H070 AUX
CH-KSP   0100.0%
H071 Terminal selection PI 
integral gain setting
Range is 0 to 99.9 / 100.0 to 
999.9 / 1000%
✔ ✔
100.0
100.0
100.0
%
>H071 AUX
CH-KSI   0100.0%
H072 Terminal selection P 
proportional gain setting
Range is 0.00 to 10.00
✔ ✔ 1.00 1.00 1.00
>H072 AUX
CH-KSPP   001.00
“H” Function
Run 
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name
Description
–FE
(CE)
–FU
(UL)
–FR
(Jpn)