Grizzly G9969 Manual De Usuario

Descargar
Página de 44
G9969
 
Radial Drill Press
-9-
Serious  personal  injury  could  occur  if  you 
connect  the  machine  to  the  power  source 
before you have completed the set up pro-
cess.  DO  NOT  connect  the  machine  to  the 
power source until instructed to do so.
110/220V Operation
SECTION 2: CIRCUIT REQUIREMENTS
Amperage Draw
The Model G9969 features 110/220V motor that 
is  prewired  for  110V  and  draws  the  following 
amps under maximum load:
Motor Draw at 110V ............................... 10 Amps
Motor Draw at 220V ................................5 Amps
Figure 2. NEMA 6-15 plug and outlet.
ALWAYS  remove  light 
bulb  if  converting  to 
220V. If the light socket 
is used while operating 
at  220V,  the  light  bulb 
WILL EXPLODE, poten-
tially  causing  serious 
personal injury.
Circuit Requirements
We recommend using a dedicated circuit for this 
machine.  You  MUST  connect  your  machine  to  a 
grounded  circuit  that  is  rated  for  the  amperage 
given  below.  Never  replace  a  circuit  breaker  on 
an  existing  circuit  with  one  of  higher  amperage 
without consulting a qualified electrician to ensure 
compliance with wiring codes. 
If you are unsure 
about  the  wiring  codes  in  your  area  or  you 
plan to connect your machine to a shared cir-
cuit, consult a qualified electrician.
110V Circuit ...........................................15 Amps
220V Circuit ...........................................15 Amps
Plug Type
The Model G9969 comes prewired with a NEMA 
5-15 plug. If you wish to rewire the motor to 220V 
we  recommend  using  the  following  plug  (see 
Figure 2 for an example):
220V Plug & Outlet ............................NEMA 6-15