Cisco Systems 2130 Manual De Usuario

Descargar
Página de 116
4-20
Cisco Application Deployment Engine (ADE) 2130 and 2140 Series Appliance Hardware Installation Guide
78-18579-02
Chapter 4      Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options
    Completing the Installation
Figure 4-10
Blank Filler Panel and AC Power Module
Step 3
Slide the new power supply into the appliance chassis until it clicks into place.
Step 4
Save the blank filler panel, in case you need to use it at a later date.
Note
A blank filler panel is shown next to an AC power supply module (see 
). The blank filler 
panel can also be used alongside a DC power module.
Completing the Installation
To complete your installation, you must reinstall the Cisco ADE 2130 and 2140 Series appliance cover 
and connect all external cables. Follow the instructions in this section.
Caution
To maintain proper cooling and airflow, install the appliance cover before turning on the appliance. 
Operating the appliance for extended periods (over 30 minutes) with the appliance cover removed might 
damage the appliance components.
Warning
The covers are an integral part of the safety design of the product. Do not operate the unit without the 
covers installed. 
Statement 1077
Installing the Cover
To install the appliance cover after you have completed your hardware options installation or 
maintenance:
Step 1
Review the information in the 
.
1
Release tabs
1
232066
1