GAS SHIELDING ISSUES
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
TROUBLESHOOTING & REPAIR
F-7
F-7
LN-25™ PRO
No shielding gas.
1. The gas supply is off or empty.
2. The gas hose is cut or crushed.
3. The  flow  meter  is  closed.    Dirt
or debris is in the solenoid.
4. There  is  a  loose  connection  at
the solenoid.
5. The solenoid has failed.
1. Verify the gas supply is ON and
flowing.
2. Reroute  the  gas  hose  to  avoid
sharp  corners  and  make  sure
nothing  is  on  it.    Repair  or
replace damaged hoses.
3. Open the flow meter valve.
4. Apply 80 psi of filtered air to the
solenoid  to  remove  dirt  and
debris.
5. Remove  the  cover  and  verify
that  all  the  connections  are  in
good condition.
6. Perform  the  GAS  SOLENOID
TEST, replace if necessary.