Metrologic Instruments MS1690 Focus Manual De Usuario

Descargar
Página de 56
 
 
28 
D
ESIGN 
S
PECIFICATIONS
 
   
 
MS1690
 
S
ERIES 
D
ESIGN 
S
PECIFICATIONS
 
M
ECHANICAL
 
 
Height:  183 mm (7.2") 
Handle 
30 mm (1.2") 
Width: 
Head 
79 mm (3.1") 
Depth:  111 mm (4.9") 
Weight:  225 g (8.0 oz) 
Termination:  10 pin modular RJ45 
Cable:  Standard 2.7 m (9') Coiled; Optional 2.1 m (7') Straight 
E
LECTRICAL
 
 
Input Voltage:  5.0VDC  ± 0.25V 
Peak = 2 W  (Typical) 
Operating = 1.65 W (Typical) 
Power: 
Idle / Standby = 800 mW (Typical) 
Peak = 400 mA (Typical) 
Operation =
 
330 mA (Typical) 
Current: 
Idle / Standby = 160 mA (Typical) 
DC Transformer:  Class 2; 5.2VDC @ 1 A 
For Regulatory Compliance information, see pages 41 - 43.  
E
NVIRONMENTAL
 
 
Operating = 0°C to 40° (32° to 104°F) 
Temperature: 
Storage = -40°C to 60°C (-40°F to 140°F) 
Humidity:  0% to 95% Relative Humidity, Non-Condensing 
Light Levels:  Up to 100,000 Lux (9,290 Footcandles)
 
 
Shock:  Designed to withstand 1.5 m (5 ft.) drops 
Contaminants:  Sealed to resist airborne particulate contaminants 
Ventilation: None 
required 
 