Citizen CL-E700 Series Manual De Usuario

Descargar
Página de 90
50
Chapter 2 Printer Operation
Top Menu
Sub Menu
Default
Menu
Remarks
Option 
Interfaces
RS-232C Baud
9600
115200
57600
38400
19200
9600
4800
2400
Setting the baud rate of the serial interface.
• All settings related to the interface are 
enabled after the power is reconnected.
RS-232C Parity
None
None
Odd
Even
Setting the communication parity for the 
serial interface.
RS-232C Length
8 bits
8 bits
7 bits
Setting the character length for the serial 
interface.
RS-232C Stopbit
1 bit
1 bit
2 bits
Setting the stop bit for the serial interface.
RS-232C X-ON
Yes
Yes
No
Selectively setting the X-ON flow control of 
the serial interface.
IEEE1284 *
On
On
Off
Setting both direction of the Centro
Interface.
Web Monitor *
Auto
Auto
On
Off
Selecting the web monitor function.
Network Address ** –
000.000.000.000 to 
255.255.255.255
Setting fixed IP address of the LAN board.
Subnet Mask **
000.000.000.000 to 
255.255.255.255
Setting fixed subnet mask value of the LAN
board.
Gateway Address ** –
000.000.000.000 to 
255.255.255.255
Setting fixed default gateway address of 
the LAN board.
BOOTP **
On
Off
Setting the BOOTP of the LAN board.
DHCP **
On
Off
Setting the DHCP of the LAN board.
WLAN Mode ***
Auto
Ad-Hoc
Infrastructure
Wireless LAN mode setting.
WLAN Channel *** –
01 to 14
Wireless LAN channel setting.
WLAN SSID ***
Max. 32 characters
SSID setting of Wireless LAN.
* If the parallel board or multi-function LAN board is mounted.
** If the multi-function LAN board is mounted, or during web monitor function.
***When the multi-function wireless LAN board is available and when Web monitor is operating.
Note: Settings related to interface are enabled after restart or after power is connected again.
Mode Settings
[Zebra® Emulation]