3M M2256PW Manual De Usuario

Descargar
Página de 41
3M™ Multi-touch Display M2256PW User Guide 
 
25 
3M Touch Systems, Inc. Proprietary Information – 37531 Rev D
POC Status – The status of the Power-on Checks.  Various controller systems are 
checked at power-up. If any failures in these systems are detected, a POC flag is set. The 
POC status field reports the state of these flags. 
Table 7. Power On Check Bit Fields 
Bit Number 
Description 
Notes 
0 Not 
used 
 
ROM_ERROR 
Code area checksum error 
PWM Error      
Touch screen not connected or potential problem 
NOV_ERROR 
Parameter blocks checksum error 
HDW_ERROR 
Problem with ADCs 
5--7 Not 
used 
 
Cmd Status – The status for the last command request. This field is used to determine 
whether the last request was processed successfully. It is also used to track the progress 
of a multi-stage request, such as 2 point calibration. The Status Request does not affect 
the contents of this field, i.e., successful or unsuccessful processing of a previous status 
request does not cause the command status field to be updated. 
Table 8. Valid Command Status Field Entries 
Response 
Description 
Failure in command processing 
Command being processed 
Stage 1 processing complete (for multi-stage commands) 
3 Command 
complete 
4  
Soft Reset Occurred 
Hard Reset Occurred 
6 -- 7 
Not used 
Get Feature - GetMaxCount 
This is a request to send information that indicates the maximum number of 
simultaneous touches supported by the controller. 
Table 9. Setup Stage 
Offset 
Field 
Size 
Value 
Description 
0 bmRequestType 
0xA1 
Class,D2H,Interface 
1 bRequest  1 
0x01 
Get 
Report 
2 wValue 
0x0312 
msb=03=Feature 
 
lsb=12 Feature Report ID 
4 wIndex 
0 Always 
6 wLength 
2 Always