3M Touch Systems, Inc. Proprietary Information – 37531 Rev D
3M Touch Systems recommends that the host system issue a Reset command whenever 
the host system is powered on and is attempting to establish communication with the 
controller. 
The amount of time needed to execute a Reset command is typically 500 milliseconds 
with a defined maximum of 2000 milliseconds. Therefore, the application program 
should wait and be sure it receives the command response before issuing another 
command to the controller following the reset. 
Restore Defaults 
Syntax:
<SOH>RD<CR> 
Response:
<SOH>0<CR> Positive response. 
Description:
Returns to the factory default operating parameters. The Restore Defaults command 
copies the 3M Touch Systems factory default parameters from ROM to the non-volatile 
memory (NOVRAM) and then executes a Reset command. 
The following table lists the factory defaults for the PX controller. The Restore Defaults 
command is useful in situations where inadvertent commands to the controller have 
rendered the sensor inoperative. 
Table 18  PX Factory Default Settings 
Operating Parameter 
Default 
Baud Rate 
115,200 
Serial Communication Settings 
N, 8, 1 
Data Format 
Format Tablet Multitouch 
Operating Mode 
Mode Stream 
Return to Factory Calibration 
Yes 
Note: After you issue a Restore Defaults command, you must recalibrate your sensor. 
Unit Type 
<SOH>UT<CR> 
Responds with an 8-character identity string. This string identifies the type of controller 
currently attached to the system, lists the features supported by the controller, and 
outputs the status of the controller hardware (a self-test code). 
Returns an identification code up to 8 ASCII characters in the following format: 
<SOH>TtFfffSs<CR> 
where: 
Tt 
=  Two ASCII characters that identify the controller type.