7.2  Clock Input Requirements
Figure 7-13: Clock Input Requirement
Note
When CLKI is more than 40MHz, REG[19h] bit 2 must be set to 1 (MCLK = CLKI/2).
Table 7-13: Clock Input Requirements for CLKI divided down internally (MCLK = CLKI/2)
Symbol
Parameter
Min
Max
Units
T
OSC
Input Clock Period 
12.5
ns
t
PWH
Input Clock Pulse Width High 
5.6
ns
t
PWL
Input Clock Pulse Width Low 
5.6
ns
t
f
Input Clock Fall Time (10% - 90%)
5
ns
t
r
Input Clock Rise Time (10% - 90%)
5
ns
Table 7-14: Clock Input Requirements for CLKI
Symbol
Parameter
Min
Max
Units
T
OSC
Input Clock Period 
25
ns
t
PWH
Input Clock Pulse Width High 
11.3
ns
t
PWL
Input Clock Pulse Width Low
11.3
ns
t
f
Input Clock Fall Time (10% - 90%)
5
ns
t
r
Input Clock Rise Time (10% - 90%)
5
ns
t
PWL
t
PWH
t
f
tr
T
OSC
V
IH
VIL
10%
90%