Seagate ST9120821SB Manual De Usuario
10
Momentus 5400.2 SATA Blade Server Product Manual, Rev. B
2.9.3
Conducted noise
Input noise ripple is measured at the host system power supply across an equivalent 15-ohm resistive load on
the +5 volt line.
the +5 volt line.
Using 5-volt power, the drive is expected to operate with a maximum of 100 mV peak-to-peak square-wave
injected noise at up to 10 MHz.
injected noise at up to 10 MHz.
Note.
Equivalent resistance is calculated by dividing the nominal voltage by the typical RMS read/write
current.
current.
2.9.4
Voltage tolerance
Voltage tolerance (including noise):
5V
±
5%
2.10
Environmental specifications
2.10.1
Ambient temperature
Ambient temperature is defined as the temperature of the environment immediately surrounding the drive.
Actual drive case temperature should not exceed
Actual drive case temperature should not exceed
65°C (149°F) within the operating ambient conditions.
Above 1,000 feet (305 meters), the maximum temperature is derated linearly by 1°C every 1000 feet.
2.10.2
Temperature gradient
2.10.3
Humidity
2.10.3.1
Relative humidity
2.10.3.2
Wet bulb temperature
2.10.4
Altitude
Operating:
5° to 40°C (41° to 104°F)
Nonoperating:
–40° to 70°C (–40° to 158°F)
Operating
20°C per hour (68°F per hour max), without condensation
Nonoperating
30°C per hour (86°F per hour max), without condensation
Operating
5% to 90% noncondensing (30% per hour max)
Nonoperating
5% to 95% noncondensing (30% per hour max)
Operating
30°C (86°F max)
Nonoperating
40°C (104°F max)
Operating
–304.8 m to 3,048 m (–1,000 ft to 10,000+ ft)
Nonoperating
–304.8 m to 12,192 m (–1,000 ft to 40,000+ ft)