Cisco Systems OL-7822-06 Manual De Usuario

Descargar
Página de 64
4-12
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 4      Connect the Management Interfaces and Perform Initial System Configuration
  Perform the Initial System Configuration
Would you like to enter the DNS configuration menu? [no]: y
Enable IP DNS-based hostname translation? [yes]:
Enter default domain name []: pcube.com
Enter Primary DNS IP address: 10.1.1.230
Would you like to add another Name Server? [no]:
Step 6: Configuring the RDR Formatter Destination    
The SCE 1000 passes Raw Data Records (RDRs) to an external collection system via the 
RDR-Formatter. In order for the data to reach the correct location, the IP address of the external 
collection system and its port number must be configured.
Step 1
Enter the RDR formatter configuration menu.
Would you like to enter the RDR-formatter configuration menu? [no]: y
Type 
and press press Enter.
The RDR-formatter destination dialog begins.
Step 2
Specify the IP address of the RDR-formatter destination.
Type the IP address of the RDR-formatter destination and press press Enter.
Enter RDR-formatter destination’s IP address:
Note that there is no default for this parameter.
Step 3
Specify the TCP port number of the RDR-formatter destination.
Type the TCP port number of the RDR-formatter destination and press press Enter.
Note that there is no default for this parameter.
Enter RDR-formatter destination’s TCP port number:
EXAMPLE:    
Following is a sample RDR-formatter configuration dialog, assigning the IP address and TCP port 
number.
Would you like to enter the RDR-formatter configuration menu? [no]: y
Enter RDR-formatter destination’s IP address: 10.1.1.230
Enter RDR-formatter destination’s TCP port number: 33000
Step 7: Configuring Access Control Lists (ACLs)    
Information About Access Control Lists