Cisco Systems OL-7822-06 Manual De Usuario

Descargar
Página de 64
8-2
Cisco Service Control Engine 1000 2xGBE Quick Start Guide
OL-7822-06
Chapter 8      Troubleshoot Startup Problems
  SCE 1000 Operational Status
Warning
SCE 1000 is fully operational (as 
above) but one of the following 
occurred:
Line ports (GBE ports) to 
the link are down
Management port link is 
down
Temperature raised above 
threshold
Voltage not in required 
range
Fans problem
Power supply problem
Insufficient space on the 
disk
Note
If the condition that 
caused the SCE 1000 to 
be in Warning state is 
resolved (for example, 
link is up) the SCE 1000 
reverts to Operational 
state.
Flashing orange
Failure
System is in Failure state after 
Boot due to one of the following 
conditions:
Power on test failure
Three abnormal reboots in 
less than 20 minutes
Platform configured to enter 
Failure mode consequent to 
failure-induced reboot (this 
is configurable using CLI 
command)
Note
Depending on the cause 
of failure, the 
management interface 
and the platform 
configuration may or 
may not be 
active/available.
Red
Table 8-1
SCE 1000 Operational States  (continued)
SCE 1000 Operational Status
Description
Status LED State