Hitachi HUA722050CLA330/1 Manual De Usuario

Descargar
Página de 258
Hitachi hard disk drive specifications   
250 
 
Output Parameters To The Device 
Feature Current 
 
      URG (bit7) 
URG  specifies  an  urgent  transfer  request.    The  Urgent  bit  specifies  that  the 
command should be completed in the minimum possible time by the device and 
shall be completed within the specified Command Completion Time Limit. 
      WC    (bit6) 
WC specifies Write Continuous  mode  enabled.    If  the Write Continuous  bit  is 
set to one, the device shall not stop execution of the command due to errors. 
If the WC bit is set to one and errors occur in transfer or writing of the data, the 
device shall continue to transfer the amount of data requested and then provide 
ending status  with BSY  bit cleared to zero, the  SE  bit set to one, the  ERR bit 
cleared to zero, and the type of error, IDNF or ABRT reported in the error log. 
If the WC bit is set to one and the Command Completion Time Limit expires, the 
device shall stop execution of the command and provide ending status with the 
BSY bit cleared to zero, the SE bit set to one, the ERR bit cleared to zero, and 
report the fact that the Command Completion Time Limit expired by setting the 
CCTO bit in the error log to one. 
In all cases, the device shall attempt to transfer the amount of data requested 
within the Command Completion Time Limit even if some data transferred is in 
error. 
      F (bit5) 
F specifies  that all  data for the specified stream shall  be flushed to the media 
before command complete is reported when set to one. 
      HSE (bit4) 
HSE (Handle Stream Error) specifies that this command starts at the LBA of the 
last  reported  error  for  this  stream,  so  the  device  may  attempt  to  continue  its 
corresponding error recovery sequence where it left off earlier. 
      Stream ID (bit 0..2) 
Stream  ID  specifies  the  stream  being  written.    The  device  shall  operate 
according to the Stream ID set by the Write Stream command.   
Feature Previous 
The time allowed for the current command's completion is calculated as follows: 
      Command  Completion  Time  Limit  =  (content  of  the  Feature  register                                 
Previous) * (Identify Device words (99:98)) useconds 
If  the  value  is  zero,  the  device  shall  use  the  Default  CCTL  supplied  with  a 
previous Configure Stream command for this Stream ID.    If the Default CCTL   
is zero, or no previous Configure Stream command was defined for this Stream 
ID, the device will ignore the CCTL.    The time is measured from the write of the 
command register to the final INTRQ for command completion. The device has 
minimum  CCTL  value. When  the  specified  value  is  shorter  than  the  minimum 
value,  CCTL  is  set  to  the  minimum  value.  Actual  minimum  CCTL  value  is 
described in the 
“Deviations from Standard” section. 
Sector Count Current 
The number of continuous sectors to be transferred low order, bits (7:0) 
Sector Count Previous 
The number of continuous sectors to be transferred high order, bits (15:8).    If 
zero  is  specified  in  the  Sector  Count  register,  then  65,536  sectors  will  be 
transferred. 
Sector Number Current  LBA (7:0). 
Sector Number Previous  LBA (31:24). 
Cylinder Low Current 
LBA (15:8). 
Cylinder Low Previous 
LBA (39:32). 
Cylinder High Current 
LBA (23:16). 
Cylinder High Previous 
LBA (47:40).