Component Identification 
4-12 
HP StorageWorks Modular Smart Array 500 System Maintenance and Service Guide 
  
 
HP CONFIDENTIAL Codename: Aurora Part Number: 251850-004 Last Saved On: 9/19/03 11:00 AM 
 
Hot-Plug SCSI Hard Drive LEDs 
1
2
3
 
 
Table 4-11:  Hot-Plug SCSI Hard Drive LEDs 
Item LED 
Description 
1 Activity 
2 Online 
3 Fault 
Hot-Plug SCSI Hard Drive LED Combinations 
 
Table 4-12:  Hot-Plug SCSI Hard Drive LED Combinations 
Activity LED 
Online LED 
Fault LED 
Status 
On Flashing 
Off 
Do not remove the drive. Removing a drive during this process 
can cause data loss in non-fault-tolerant configurations 
• 
The drive is a replacement drive and is being rebuilt or 
• 
If all online LEDs in a drive array are flashing, an expansion is 
occurring. 
Off 
Off 
On 
OK to replace the drive online. 
The drive has failed and has been placed offline. 
Off, on, or 
flashing 
On Off 
Do not remove the drive. Removing a drive during this process 
can cause data loss in non-fault-tolerant configurations.
 
The drive is online and configured as part of an array. 
Off, on, or 
flashing 
On or Off 
Flashing 
A predictive failure alert has been received for this drive. Replace the 
drive as soon as possible.