National Instruments 321042A-01 Manual De Usuario

Descargar
Página de 53
Chapter 4
Installation Verifica tion and Troubleshooting
© National Instruments Corp.
4-5
STD-GPIB for Windows
Presence Test of Software Components
The Software Diagnostic Test checks for the presence of 
ni-pnp.ini
gpib.ini
 and
gpib.dll
.
If the 
ni-pnp.ini
 file is not found in the root of the boot drive, the following error
message is displayed:
An unexpected ERROR occurred:
Unable to locate NI-PNP.INI
Try reinstalling the NI-488.2 software.
If the 
gpib.ini
 file is not found in the Windows directory, the following error message
is displayed:
An unexpected ERROR occurred:
Unable to locate GPIB.INI in the Windows directory:  C:\WINDOWS.
Try reinstalling the NI-488.2 software.
If the 
gpib.dll
 file is not found in either the Windows or the Windows System
directory, the following error message is displayed:
An unexpected ERROR occurred:
Unable to locate GPIB.DLL in the Windows or Windows system
directory.
Try reinstalling the NI-488.2 software.
If you get any of these messages, you must reinstall the NI-488.2 software.
Presence Test of Driver
The Software Diagnostic Test displays the following message when it fails because of a
mismatch between 
gpib.ini
 and 
gpib.dll
:
<<<  No handler present for GPIB
x.  >>>
If this message appears, you should reinstall the NI-488.2 software.
Presence Test of Module
The following error message appears if 
gpib
x
 is not installed or if the software is not
configured properly:
<<<  No board present for GPIB
x.  >>>