Cisco Systems 1552H Manual De Usuario

Descargar
Página de 164
 
2-44
Cisco Aironet 1550 Series Outdoor Mesh Access Point Hardware Installation Guide
OL-24247-01
Chapter 2      Installing the Access Point
  Connecting a Fiber-Optic Cable to the Access Point
Step 6
Loosen the round end of the liquid-tight connector by turning counterclockwise, but do not remove (see 
Figure 2-33
Liquid -Tight Adapter
Step 7
Carefully screw the threaded end of the adapter into the access point and hand-tighten.
Step 8
Use an adjustable wrench, the 22 mm socket, or the Sealcon S-2200-WR wrench to tighten the threaded 
end of the adapter to 6 to 7 ft lbs (8.1 to 9.5 Nm).
Step 9
Carefully remove approximately 1 to 2 ft (30.5 cm) of the external jacket from the fiber-optic cable, 
exposing the inner strand.
Step 10
Carefully insert the fiber-optic LC cable connector into the rounded end of the liquid-tight adapter (see 
), and push through the adapter.
Step 11
Wrap excess fiber-optic cable around the take-up reels in a figure eight (8) pattern.
Step 12
Insert the fiber-optic LC cable connector into the SFP module.
Step 13
Use an adjustable or open-end wrench to tighten the round end of the adapter to 2.7 to 3.2 ft lbs
(3.66 to 4.34 Nm).
Step 14
Close the hinged cover (see the 
1
Thread end
2
Round end