Chapter 15      Managing System Operations and Configuration in the Monitoring and Report Viewer
  Understanding Collection Filters
Understanding Collection Filters
You can create collection filters that allow you to filter and drop syslog events that are not used for 
monitoring or troubleshooting purposes. When you configure collection filters, the Monitoring and 
Report Viewer does not record these events in the database and thus saves much needed disk space. 
Note
ACS 5.4 supports collecting syslog messages from IPv6 sources. 
This section contains the following topics:
Creating and Editing Collection Filters
Use this page to create or edit collection filters. To do this:
Step 1
From the Monitoring and Report Viewer, choose Monitoring Configuration > System Configuration 
> Collection Filters
.
The Collection Filters page appears.
Step 2
In the Filters area, do one of the following:
Click Create to create a collection filter.
Check the check box of the syslog attribute that you want to edit, then click Edit.
Check the check box of the syslog attribute that you want to delete, then click Delete.
The Add or Edit Collection Filters page described in 
 appears.
Table 15-11
Add or Edit Collection Filters Page
Option
Description
Syslog Attribute
In the Add Filter page, choose any one of the following syslog attributes:
NAS IP Address—IPv4 and IPv6 addresses are supported. 
Access Service
MAC Address
User
In the Edit Filter page, this field is Display only.
Value
Enter the value of the syslog attribute:
NAS IP Address—Enter the IP address of the NAS that you want to filter.
Access Service—Enter the name of the access service that you want to filter.
MAC Address—Enter the MAC address of the machine that you want to filter.
User—Enter the username of the user you want to filter.