Cisco Systems 15454M6DC Manual De Usuario

Descargar
Página de 458
 
8-16
Cisco ONS 15454 Installation and Operations Guide
November 2001
Chapter 8      Performance Monitoring
Performance Monitoring for Electrical Cards
UAS-L
Near-End Line Unavailable Seconds (UAS-L) is a count of the seconds 
when the line is unavailable. A line becomes unavailable when ten 
consecutive seconds occur that qualify as SES-Ls, and the line continues 
to be unavailable until ten consecutive seconds occur that do not qualify 
as SES-Ls.
FC-L
Near-End Line Failure Count (FC-L) is a count of the number of near-end 
line failure events. A failure event begins when an AIS-L failure or a 
lower-layer, traffic-related, near-end failure is declared. This failure event 
ends when the failure is cleared. A failure event that begins in one period 
and ends in another period is counted only in the period where it begins.
Table 8-4
Near-End SONET Path PMs for the EC1 Card
Parameter
Definition
Note
SONET path PMs will not count unless IPPM is enabled. For additional information, see the 
The far-end 
IPPM feature is not supported in Software R3.1. However, SONET path PMs can be monitored 
by logging into the far-end node directly.
STS CV-P
Near-End STS Path Coding Violations (CV-P) is a count of BIP errors 
detected at the STS path layer (i.e., using the B3 byte). Up to eight BIP 
errors can be detected per frame; each error increments the current CV-P 
second register.
STS ES-P
Near-End STS Path Errored Seconds (ES-P) is a count of the seconds 
when at least one STS path BIP error was detected. STS ES-P can also be 
caused by an AIS-P defect (or a lower-layer, traffic-related, near-end 
defect) or an LOP-P defect. 
STS FC-P
Near-End STS Path Failure Counts (FC-P) is a count of the number of 
near-end STS path failure events. A failure event begins when an AIS-P 
failure, an LOP-P failure, a unequipped path (UNEQ-P) or a trace 
identifier mismatch (TIM-P) failure is declared. A failure event also 
begins if the STS PTE monitoring the path supports ERDI-P for that path. 
The failure event ends when these failures are cleared.
STS SES-P
Near-End STS Path Severely Errored Seconds (SES-P) is a count of the 
seconds when K (2400) or more STS path BIP errors were detected. STS 
SES-P can also be caused by an AIS-P defect (or a lower-layer, 
traffic-related, near-end defect) or an LOP-P defect.
STS UAS-P
Near-End STS Path Unavailable Seconds (UAS-P) is a count of the 
seconds when the STS path was unavailable. An STS path becomes 
unavailable when ten consecutive seconds occur that qualify as SES-Ps, 
and it continues to be unavailable until ten consecutive seconds occur that 
do not qualify as SES-Ps.
Table 8-3
Near-End Line Layer PMs for the EC1 Card (continued)
Parameter
Definition