Cisco Systems 15454M6DC Manual De Usuario

Descargar
Página de 458
 
8-23
Cisco ONS 15454 Installation and Operations Guide
November 2001 
Chapter 8      Performance Monitoring
Performance Monitoring for Electrical Cards
Figure 8-16 PM read points on the DS3 and DS3N cards
Table 8-13 Near-End DS3 Line PMs for the DS3 and DS3N Cards
Parameter
Definition
DS3 CV-L
Code Violation Line (CV-L) indicates the number of coding violations 
occurring on the line. This parameter is a count of bipolar violations 
(BPVs) and excessive zeros (EXZs) occurring over the accumulation 
period.
DS3 ES-L
Errored Seconds Line (ES-L) is a count of the seconds containing one or 
more anomalies (BPV + EXZ) and/or defects (loss of signal) on the line.
DS3 SES-L
Severely Errored Seconds Line (SES-L) is a count of the seconds 
containing more than a particular quantity of anomalies (BPV + EXZ > 
44) and/or defects on the line.
DS3 LOSS-L
Line Loss of Signal (LOSS-L) is a count of one-second intervals 
containing one or more LOS defects.
Table 8-14 Near-End DS3 Path PMs for the DS3 and DS3N Cards
Parameter
Definition
DS3 ES-P
Errored Seconds-Path (ES-P) is a count of one-second intervals 
containing one or more CRC-6 errors, or one or more CS events, or one 
or more SEF or AIS defects. 
DS3 SES-P
Severely Errored Seconds-Path (SES-P) is a count of seconds where 320 
or more CRC-6 errors occur or one or more SEF or AIS defects occur.
DS3 SAS-P
Severely Errored Frame/Alarm Indication Signal-Path (SAS-P) is a count 
of seconds containing one or more SEFs or one or more AIS defects.
55305
ONS 15454
DS3 & DS3N Cards
LIU
Mux/Demux ASIC
BTC
ASIC
XC10G Card
OC-N
DS3 Side
Path
Level
SONET Side
STS CV-P
STS ES-P
STS FC-P
STS SES-P
STS UAS-P
DS3 CV-L
DS3 ES-L
DS3 SES-L
DS3 LOSS-L
DS3 ES-P
DS3 SES-P
DS3 SAS-P
DS3 AISS-P
DS3 UAS-P
PMs read on Mux/Demux ASIC
PMs read on LIU