Single Interrupt Mode 
This mode routes the interrupt signal from both SJA1000 CAN controllers to one PC/104 Bus 
Interrupt signal. This mode is set up by installing Jumper J1/J2 Position “S” (either the CAN-0 or 
the CAN-1 “S” position can be used). When this jumper is installed, the Interrupt signal occurs on 
the “CAN-0 row” of J1 and J2 (red box). 
 
Dual Interrupt Mode 
This mode routes the interrupt signal from the CAN-0 SJA1000 CAN controller to the CAN-0 
PC/104 Bus Interrupt signal and the CAN-1 SJA1000 CAN controller to the CAN-1 PC/104 Bus 
Interrupt signal. This mode is set up by removing Jumper J1/J2 Position “S”
 
J1/J2 Position “S”  Function 
Removed 
Dual Interrupt Mode  
Installed 
Single Interrupt Mode 
Table 15 
 
Shared Interrupt Mode 
In either the Single or Dual interrupt modes, the PC/104 Bus Interrupt Signal can be shared with a 
similarly selected interrupt on another PC/104 board (which supports shared interrupts). There are 2 
jumpers which control this sharing on J3C Positions #3 and #4
 
J3C Position 
Function 
Jumper Installed 
Jumper Removed 
CAN-1 Interrupt Shared 
CAN-1 Interrupt Not Shared 
CAN-0 Interrupt Shared 
CAN-0 Interrupt Not Shared 
Table 16 
 
Shared Interrupt Pull-Down 
When shared interrupts are employed, there MUST be one board (among the boards that share the 
same interrupt) that MUST be setup to activate a Pull-Down resistor on the Interrupt signal. This is 
accomplished by Jumper J3C Position #5
 
J3C Position #5 
Function 
Removed 
Shared Interrupt(s) Pull-Down disabled 
Installed 
Shared Interrupt(s) Pull-Down enabled 
Table 17 
 
Interrupt Selection 
In either of the CAN-0 or CAN-1 groups there is 11 possible interrupts that can be selected. The 
jumpers are numbered by the PC/104 Bus Interrupt number (3, 4, 5, 6, 7, 9, 10, 11, 12, 14 or 15). 
Only one jumper should be installed in the appropriate group. 
 
CAN Bus Dominant Timeout and Minimum Speed 
The CANpro/104 board implements a CAN Bus transceiver which has a “Dominant State timeout 
feature
”. This feature prevents the board from permanently holding the CAN bus in the “Dominant 
state”. Due to this feature, the minimum CAN Bus data rate supported is 20K bps.