Connect Tech CTIM-00043 Manual De Usuario

Descargar
Página de 25
CANpro/104 User Manual 
 
 
 
 
CTIM-00043 (0.01) 1/15/2010 
www.connecttech.com
 
 
 
22 
 
800-426-8979 | 519-836-1291 
Other On-board Jumper Selection  
Near each I/O connector a 2x2 jumper block (either J4 or J5) will allow the configuration of both bus 
termination and slew rate limiting for the transceiver. J4 configures options for CAN controller 0, while J5 
configures options for CAN controller 1. 
 
 
 
 
 
 
 
 
Installing a jumper on the first location of J4 or J5 (the gray area above) will enable a 120 Ohm termination 
resistor across the CAN-H and CAN-L lines. Termination is recommended for improved signal integrity in 
longer transmission lines. Termination requirements should be evaluated on a case by case basis. Typically 
both ends of a CAN bus are terminated, but no termination is enabled on cards that sit in the middle of the 
bus. 
 
 
 
 
 
 
Installing a jumper on the second location of J4 or J5 (the gray area above) will disable slew rate limiting for 
the associated CAN port. Slew rate limiting will reduce the emitted switching noise that is sent out onto the 
CAN bus lines and radiated from those lines. Switching noise may cause EMI / EMC incompatibilities 
depending on the cabling used to support the system.  The use of slew rate limiting may aid in a system that is 
close to the limit of emissions already.  Properly shielded cabling will dramatically reduce emissions.  
 
Slew rate limiting may only be used on busses operating at slower baud rates.  With the jumper installed, full 
1Mbps operation is possible.