GE 2300 V Manual De Usuario

Descargar
Página de 266
GEH-6385  Reference and Troubleshooting, 2300 V Drives
Chapter 4  Wizards  
••••
  4-23
Drive Commissioning: Reference Ramp
Programmed Deceleration Speeds
The programmed ramp rate implements a speed dependent ramp rate profile. The
deceleration rate depends on the magnitude of the speed reference. The rate of
change of the speed reference is limited to the deceleration rate when the magnitude
of the speed reference is decreasing.
There are three speed regions which are characterized by unique acceleration ramp
rates. Region 1 is defined for speed magnitudes less than Accel break point 1.
Region 2 is defined for speed magnitudes between Accel break point 1 and Accel
break point 2
. Region 3 is defined for speed magnitudes greater than Accel break
point 2
.
Enter values for the two parameters which set the boundaries of the speed regions.
Related functions
  Speed Reference Ramp
Drive Commissioning: DDI Increment and
Decrement Rates (Local Mode)
Local Inc/Dec rate is the rate of change in the local speed reference offset (in local
mode) when the increment (+) and decrement (-) buttons on the DDI are pressed.
Drive Commissioning: Speed/Torque Regulator
Configuration
The questions that follow select and configure the desired regulator mode. Note that
the regulator is not fully configured until the Speed Regulator Tuneup has run.
Related functions
  Speed/Torque Regulator
Drive Commissioning: Speed/Torque Regulator
Modes
Three regulator modes are available:
  Speed regulator: Speed regulator.
  Torque regulator: Torque regulator.
  Torque, spd override: Torque regulator with speed override.
When the speed regulator mode is active, the drive controls the motor speed so that it
follows the speed command. When the torque regulator mode is active, the drive sets
the output of the regulator to a selected torque reference signal. The torque with
speed override mode is similar to the torque regulator mode, except that the drive
begins to control the speed when the difference between the speed command and the
speed feedback is too large.
Select Speed regulator to activate the speed regulator mode. Select Torque regulator
to activate the torque regulator mode. Select Torque, spd override to activate the
torque regulator with speed override mode.