Cisco Systems 1550 Manual De Usuario

Descargar
Página de 164
 
2-58
Cisco Aironet 1550 Series Outdoor Mesh Access Point Hardware Installation Guide
OL-24247-01
Chapter 2      Installing the Access Point
  Powering the Access Point
Figure 2-44
Inserting the Terminal Strip into the DC Power Opening in the Access Point Case
Step 9
Slide the liquid-tight adapter towards the access point, and screw the threaded end of the adapter into the 
access point, and hand-tighten.
Step 10
Use an adjustable wrench, a 22-mm socket, or a Sealcon S-2200-WR wrench to tighten the threaded end 
of the adapter to 6 to 7 ft lbs (8.1 to 9.5 Nm).
Step 11
Use an adjustable or open-end wrench to tighten the round end of the adapter to 2.7 to 3.2 ft lbs (3.66 to 
4.34 Nm).
Step 12
Ensure that the antennas are connected to the access point before you apply power to the access point.
Step 13
Turn on the DC power at the designated circuits.
Connecting a Cable POC Power to the Access Point
The cable configuration on a 1552C or 1552CU access point contains a cable modem and RF splitter but 
does not contain a cable stinger connector. The cable stinger connector is customer supplied.
Note
To ensure system performance, with respect to immunity from external electromagnetic fields, the 
installer must use a well shielded coax cable (quad shield). 
Note
The POC access point is classified as a type “Hazardous Voltage Secondary” circuit as per the 
UL/IEC/EN 60950-1 safety standard. The cable distribution network used with this access point must 
provide transient reduction to the level for this type of circuit classification (that is, 500V 
transient/lightning surge).
1
Two-position terminal strip
3
Liquid-tight adapter
2
DC power cable
4
DC power opening in access point case