Address Translation Unit (PCI Express)—Intel
®
 413808 and 413812
Standard Messages accepted by SRL as target
ERR_COR
Signal detection of a correctable error 
to Root Complex
RC
Log in PCI Express Advanced 
Error registers and interrupt the 
core via the root interrupt bit in 
the ATUISR
ERR_NONFATAL
Signal detection of an uncorrectable 
error Root Complex
RC
ERR_FATAL
Signal detection of a fatal error Root 
Complex
RC
PM_Active_State_NAK
Rejection of request to enter a low 
power state
End 
Point
PME_Turn_Off
Notification of pending turn-off of link 
clock and power
End 
Point
Generate PME_TO_Ack message.
PM_PME
PME message conveying the ID of the 
PME originator
RC
Log in requester ID in the Root 
Status Register. Interrupt the 
core via the Root Complex 
interrupt bit in the ATUISR 
PME_TO_Ack
c
Acknowledge turn-off of link clock and 
power
RC
Assert_INTx
Assert INTx virtual signal
RC
Captured and converted to 
signals to Interrupt Controller
Deassert_INTx
De-assert INTx virtual signal
RC
Set_Slot_Power_Limit
Set Slot Power Limit in Upstream Port End 
Point
Copy payload to Device 
Capabilities register and 
interrupt the core.
Vendor Defined Message 
Type 0/1
Vendor Specific Message. It is used by 
devices to communicate with SRL 
device core.
RC,
End 
Point
Log in Inbound Vendor Message 
Register and interrupt the core.
Attention_Indicator_X
These messages are issued by the 
root port to change the indicator on 
the device
End 
Point
Log in the PEMCSR, and 
interrupt the core
Power_Indicator_X
These messages are issued by the 
root port to change the indicator on 
the device
End 
Point
Log in the PEMCSR, and 
interrupt the core
Attention_Button_Pressed Issued by endpoint when button 
pressed on device
RC
Log in Slot Status Register and 
interrupt core
a. As a Root Complex, system software never requests SRL to broadcast the 
PME_Turn_Off message in preparation for removing the main power and clock 
sources. Thus, SRL doesn’t generate this message as a RC. However, for reuse 
purpose the Message Unit is capable of generating this message. 
b. As an End Point, SRL never generates a PM_PME message to the RC. It means SRL 
doesn’t consume AUX power. However, for reuse purpose the Message Unit is 
capable of generating this message.
c. SRL doesn’t generate PME_Turn_Off message. Thus it shouldn’t receive 
PME_TO_Ack Message. However, for reuse purpose the Message Unit is capable of 
accepting this message.
Table 125. Supported Message Types (Sheet 2 of 2)
Message
Description/ Comments
RC or 
End 
Point
Comment