 3 Functional Description
PrPMC800/800ET Processor PMC Module Installation and Use (PrPMC800A/IH5)
23
   
PrPMC800/800ET Power Supplies
The PrPMC800/800ET
 
module requires only a +3.3V input voltage. The processor core voltage 
and the Harrier core voltage are generated on the module from the +3.3V input using the 
LTC1702 dual synchronous switching regulator. In addition to the Harrier core voltage, the 
+2.5V supply provides the processor, Harrier, and L2 cache I/O voltages.
Module Reset Logic
A block diagram of the PrPMC800/800ET
 
module reset logic appears in 
There are five standard sources of reset on the PrPMC800/800ET. They are:
1. Power-Up reset
2.
PMC PCI RST#
3.
Watchdog Timer reset via the Harrier Watchdog 1 Timer output
4.
Software generated module reset from Harrier RSTOUT control bit
5.
Debug RESET_L signal from debug header
The following table describes the function of each reset source. A module reset includes the 
processor, Harrier and Ethernet. The RESETOUT_L pin must be tied into the baseboard reset 
logic, which drives PCIRST# in order to produce module reset.
Table 3-4. Reset Source Functions
Reset Source Type
Module Reset
PrPMC RESETOUT_L 
Active
Power-Up Reset
x
x
PMC PCI RST#
x
WDT1 Timer Output
x
SW Reset
x
Debug Reset
x