National Instruments PCI-1200 Manual De Usuario

Descargar
Página de 100
Chapter 3
Signal Connections
© National Instruments Corporation
3-29
Mode 1 Output Timing
The timing specifications for an output transfer in mode 1 are as follows: 
Figure 3-18.  Mode 1 Timing Specifications for Output Transfers
Name
Description
Minimum
Maximum
T1
WRT* = 0 to INTR = 0
450
T2
WRT* = 1 to output
350
T3
WRT* = 1 to OBF* = 0
650
T4
ACK* = 0 to OBF* = 1
350
T5
ACK* pulse width
300
T6
ACK* = 1 to INTR = 1
350
All timing values are in nanoseconds.
WRT*
OBF*
INTR
ACK*
DATA
T1
T2
T3
T4
T5