Chapter 4     Signal Connections
 National Instruments Corporation
4-49
AT-MIO/AI E Series User Manual
Figure 4-34 shows the timing requirements for the GPCTR1_SOURCE 
signal.
Figure 4-34.  GPCTR1_SOURCE Signal Timing
The maximum allowed frequency is 20 MHz, with a minimum pulse 
width of 23 ns high or low.  There is no minimum frequency limitation.
The 20 MHz or 100 kHz timebase normally generates the 
GPCTR1_SOURCE unless you select some external source.
GPCTR1_GATE Signal
Any PFI pin can externally input the GPCTR1_GATE signal, which is 
available as an output on the PFI4/GPCTR1_GATE pin.
As an input, the GPCTR1_GATE signal is configured in edge-detection 
mode.  You can select any PFI pin as the source for GPCTR1_GATE 
and configure the polarity selection for either rising or falling edge.  
You can use the gate signal in a variety of different applications to 
perform such actions as starting and stopping the counter, generating 
interrupts, saving the counter contents, and so on.
As an output, the GPCTR1_GATE signal monitors the actual gate 
signal connected to general-purpose counter 1.  This is true even if the 
gate is being externally generated by another PFI.  This output is set to 
tri-state at startup.
t
p
t
w
t
w
t
p
t
w
= 50 ns minimum
= 23 ns minimum