Appendix A. Troubleshooting
A.1 No video image is displayed on the remote monitor
•  Check the yellow indicators on the local and remote modules while no keys are pressed on the keyboard and no mouse move-
ments are being made - both indicators should be continually on when a valid video signal is present.
  LOCAL: If the yellow indicator is giving a regular flash (twice per second), then the video feed to the local module is not valid. 
Try connecting a DVI monitor (preferably using the same DVI link cable as used with the local module) directly to the computer 
and check for a correct image.
  REMOTE: If the yellow indicator is giving a regular flash (twice per second), then the video feed via the link cable is not valid. If 
the link cable is long, try using a short link cable temporarily to check for basic operation. 