Brocade Communications Systems 4016 Manual De Usuario

Descargar
Página de 54
SilkWorm 4016 Hardware Reference Manual
4-5
Publication Number: 53-1000175-01
Removing and Replacing the SilkWorm 4016
4
Removing and Replacing the SilkWorm 4016
To remove a failed or replaced SilkWorm 4016:
1.
Back up the switch configuration to an FTP server by typing the configUpload command and 
following the prompts.
This command uploads the switch configuration to the server, making it available for downloading 
to a replacement switch if necessary. Brocade recommends backing up the configuration on a 
regular basis to ensure that a complete configuration is available for downloading to a replacement 
switch. 
2.
Stop all SAN activity requiring the ports used by the SilkWorm 4016.
For details about port management, refer to your blade server documentation. Verify that there is no 
activity by viewing the SilkWorm 4016 LEDs. For details about LED activity on the SilkWorm 
4016, see 
3.
Remove all cables from the SFP modules.
4.
Remove the SFP modules according to the manufacturer’s instructions.
4
Ethernet 
speed
green
Off: 10 Mbit/sec
On: 100 Mbit/sec
5
Ethernet 
link
amber
Off: No link
On: Link OK
Blink: Rx or Tx traffic
6
FC  port  x 
status
green/amber
LED meanings are not valid during boot, diagnostics, 
or POST.
Off: No signal carrier
Amber: Signal present but not online
Slow blink amber: Disable, ~2 second interval
Fast blink amber: Error or fault with port, ~1/2 
second interval
Green: Online; flickers with activity
Slow blink green: Online but segmented
Fast blink green: Internal loopback
7
FC  port  x 
speed 
green/amber
Amber on: 4 Gbit/sec FC
Green on: 2 Gbit/sec FC
Both off: 1 Gbit/sec FC
Location
Indicator 
Color 
Operation (Continued)