If the program contains SIMPL+ or User modules, the conversion might generate 
error messages. This is because modules and programs often contain symbols with 
“ambiguous” signals. For example, the inputs of the Serial to Analog symbol can be 
defined as either analog or serial. Although X-Series processors support ambiguous 
signals, the 2-Series processor requires all signal types to be strictly defined. 
If the program you want to convert contains SIMPL+ or User modules, Crestron 
recommends that you first convert each module before converting the larger 
program. In this way, the compiler can resolve any ambiguous signals in the modules 
and minimize errors when the larger program is converted. 
Converting SIMPL+ Modules 
1.  Open the SIMPL+ module you want to convert. 
2.  Choose the 2-Series processor as the target by clicking the toolbar 
button, as shown in the following illustration.  
SIMPL+  Toolbar 
 
NOTE: Note that you can select both X and 2-Series as the targets, so that the 
module will work for both types of control systems. However, you will be limited to 
SIMPL+ keywords and functions that are supported on both systems. If you do not 
choose a target, then the module may or may not work, depending on the constructs 
that are used. 
3.  Save and compile the module by clicking the Save and Compile 
toolbar button; alternatively, click Save and Compile on the Build 
menu (or press F12). 
Converting User Modules 
1.  Open the User module you want to convert. 
2. Click 
Project | Edit Program Header
3. Click 
2-Series in the “Target Control System Classes” list box.  
 
You can select other types of control systems as well, but then you will be 
limited to symbols that are supported by all of these platforms. The module 
may still work on unselected control systems so long as unsupported 
symbols are not used. Selecting a control system means that you are 
requiring the module to work there. 
Operations Guide - DOC. 5980 