2-Series Integrated Control Processor 
 
Crestron CP2/CP2E
 
use a CAT5 crossover cable to connect the two LAN ports directly, without using a 
hub. 
Once the cable connections are made, open the Crestron Viewport and click Setup | 
Communication Settings
 on the menu to display the “Port Settings” dialog box. 
Then click TCP/IP as the connection type. Enter the IP address of the CP2E. 
 
 
 
To verify communication, click Diagnostics | Establish Communications (Find 
Rack).
 This should display a dialog box that gives the IP address and port number. 
Troubleshooting Communications 
Use the following checklist if communication cannot be established with the 
CP2/CP2E. 
1.  Verify that you are using the correct cables. As described previously, 
an RS-232 connection requires a straight-through serial cable. That is, 
pin 1 on one end is connected to pin 1 on the other end. Pin 2 connects 
to pin 2, etc. With a TCP/IP connection, you must use a CAT5 cable 
with 8-pin RJ45 connectors. 
2.  With a serial connection, verify that the correct COM port on the PC 
has been selected. Some computers have more than one COM port; 
22  
  2-Series Integrated Control Processor: CP2/CP2E 
Operations Guide - DOC. 5980