Cypress CY7C1916CV18 Manual De Usuario

Descargar
Página de 29
CY7C1316CV18, CY7C1916CV18
CY7C1318CV18, CY7C1320CV18
Document Number: 001-07160 Rev. *E
Page 22 of 29
Capacitance
Tested initially and after any design or process change that may affect these parameters.
Parameter
Description
Test Conditions
Max
Unit
C
IN
 Input 
Capacitance
T
A
 = 25
°C, f = 1 MHz, V
DD
 = 1.8V, V
DDQ 
= 1.5V
5
pF
C
CLK
Clock Input Capacitance
6
pF
C
O
Output Capacitance
7
pF
Thermal Resistance
Tested initially and after any design or process change that may affect these parameters.
Parameter
Description
Test Conditions
165 FBGA 
Package
Unit
Θ
JA
Thermal Resistance
(Junction to Ambient)
Test conditions follow standard test methods and 
procedures for measuring thermal impedance, in 
accordance with EIA/JESD51.
18.7
°C/W
Θ
JC
Thermal Resistance
(Junction to Case)
4.5
°C/W
Figure 4.  AC Test Loads and Waveforms
1.25V
0.25V
R = 50
Ω
5 pF
INCLUDING
JIG AND
SCOPE
ALL INPUT PULSES
Device
R
L
= 50
Ω
Z
0
= 50
Ω
V
REF 
= 0.75V
V
REF 
= 0.75V
0.75V
Under 
Test
0.75V
Device
Under 
Test
OUTPUT
0.75V
V
REF
V
REF
OUTPUT
ZQ
ZQ
(a)
Slew Rate = 2 V/ns
RQ =
250
Ω
(b)
RQ =
250
Ω
Note
20. Unless otherwise noted, test conditions assume signal transition time of 2V/ns, timing reference levels of 0.75V, V
REF
 = 0.75V, RQ = 250
Ω, V
DDQ 
= 1.5V, input pulse 
levels of 0.25V to 1.25V, and output loading of the specified I
OL
/I
OH
 and load capacitance shown in (a) of 
.