Cisco Systems WS-X3500-XL Manual De Usuario

Descargar
Página de 58
 
Chapter 1
Overview
Cabling Guidelines
1-4
Catalyst GigaStack Gigabit Interface Converter Hardware Installation Guide
78-6460-04
Figure 1-3
GBIC LED Location on a 1000BASE-X Module
 describes the switch and 1000BASE-X module GBIC slot LED colors 
and port status.
Cabling Guidelines
The GigaStack GBIC uses the following Cisco proprietary cables. See 
and 
 for more information.
22122
GigaStack GBIC
Tighten
Screws
To Activate
WS-X2931-XL
1000BaseX
GBIC LED
1
2
Table 1-2
Switch and 1000BASE-X Module GBIC Slot LEDs
Color
Meaning
Off
No link, or port was administratively shut down.
Green
Link present.
Flashing green
Activity. Port is transmitting or receiving data.
Alternating 
green-amber
Link fault. Error frames can affect connectivity, and errors 
such as excessive collisions, cyclic redundancy check 
(CRC) errors, and alignment and jabber errors are 
monitored for a link-fault indication.
Solid amber
Port is blocked by Spanning Tree Protocol (STP) and is not 
forwarding data.
Note
After a port is reconfigured, the port LED can 
remain amber for up to 30 seconds as STP checks 
the switch for possible loops.
Flashing amber
Port is blocked by STP and is sending or receiving packets.