Table 3-1
Common Problems and Their Solutions
Symptom
Possible Causes
Corrective Action
GBIC module slot 
LED is amber.
Spanning Tree Protocol 
(STP) is checking for loops.
Wait for STP to complete its search. The LED 
turns green when STP completes its check.
Port is initializing, it was 
disabled by management or 
an address violation, or it 
was blocked by STP.
Use the Cluster Management Suite or the IOS 
command-line interface to check the status of the 
port and to enable it.
GBIC module slot 
LED is flashing 
green and amber.
Port is experiencing error 
frames. This could be due to 
a duplex mismatch caused 
by autonegotiation, 
collisions, cyclic 
redundancy check (CRC) 
errors, or alignment errors.
Remove and reinsert the GigaStack GBIC.
GBIC module slot 
LED is off.
Device has no power.
Ensure that the switch and the target device have 
power.
No link or port was shut 
down administratively.
Verify that the GBIC cable is connected to another 
active network device and that the port is not shut 
down.
Bad cable.